12 research outputs found

    Proceedings of the Linux Audio Conference 2018

    Get PDF
    These proceedings contain all papers presented at the Linux Audio Conference 2018. The conference took place at c-base, Berlin, from June 7th - 10th, 2018 and was organized in cooperation with the Electronic Music Studio at TU Berlin

    The NORMAN Association and the European Partnership for Chemicals Risk Assessment (PARC): let’s cooperate! [Commentary]

    Get PDF
    The Partnership for Chemicals Risk Assessment (PARC) is currently under development as a joint research and innovation programme to strengthen the scientific basis for chemical risk assessment in the EU. The plan is to bring chemical risk assessors and managers together with scientists to accelerate method development and the production of necessary data and knowledge, and to facilitate the transition to next-generation evidence-based risk assessment, a non-toxic environment and the European Green Deal. The NORMAN Network is an independent, well-established and competent network of more than 80 organisations in the field of emerging substances and has enormous potential to contribute to the implementation of the PARC partnership. NORMAN stands ready to provide expert advice to PARC, drawing on its long experience in the development, harmonisation and testing of advanced tools in relation to chemicals of emerging concern and in support of a European Early Warning System to unravel the risks of contaminants of emerging concern (CECs) and close the gap between research and innovation and regulatory processes. In this commentary we highlight the tools developed by NORMAN that we consider most relevant to supporting the PARC initiative: (i) joint data space and cutting-edge research tools for risk assessment of contaminants of emerging concern; (ii) collaborative European framework to improve data quality and comparability; (iii) advanced data analysis tools for a European early warning system and (iv) support to national and European chemical risk assessment thanks to harnessing, combining and sharing evidence and expertise on CECs. By combining the extensive knowledge and experience of the NORMAN network with the financial and policy-related strengths of the PARC initiative, a large step towards the goal of a non-toxic environment can be taken

    Effects of Instantaneous Multiband Dynamic Compression on Speech Intelligibility

    Get PDF
    <p/> <p>The recruitment phenomenon, that is, the reduced dynamic range between threshold and uncomfortable level, is attributed to the loss of instantaneous dynamic compression on the basilar membrane. Despite this, hearing aids commonly use slow-acting dynamic compression for its compensation, because this was found to be the most successful strategy in terms of speech quality and intelligibility rehabilitation. Former attempts to use fast-acting compression gave ambiguous results, raising the question as to whether auditory-based recruitment compensation by instantaneous compression is in principle applicable in hearing aids. This study thus investigates instantaneous multiband dynamic compression based on an auditory filterbank. Instantaneous envelope compression is performed in each frequency band of a gammatone filterbank, which provides a combination of time and frequency resolution comparable to the normal healthy cochlea. The gain characteristics used for dynamic compression are deduced from categorical loudness scaling. In speech intelligibility tests, the instantaneous dynamic compression scheme was compared against a linear amplification scheme, which used the same filterbank for frequency analysis, but employed constant gain factors that restored the sound level for medium perceived loudness in each frequency band. In subjective comparisons, five of nine subjects preferred the linear amplification scheme and would not accept the instantaneous dynamic compression in hearing aids. Four of nine subjects did not perceive any quality differences. A sentence intelligibility test in noise (Oldenburg sentence test) showed little to no negative effects of the instantaneous dynamic compression, compared to linear amplification. A word intelligibility test in quiet (one-syllable rhyme test) showed that the subjects benefit from the larger amplification at low levels provided by instantaneous dynamic compression. Further analysis showed that the increase in intelligibility resulting from a gain provided by instantaneous compression is as high as from a gain provided by linear amplification. No negative effects of the distortions introduced by the instantaneous compression scheme in terms of speech recognition are observed.</p

    Indication criteria for cochlear implants and hearing aids: impact of audiological and non-audiological findings

    No full text
    Owing to technological progress and a growing body of clinical experience, indication criteria for cochlear implants (CI) are being extended to less severe hearing impairments. It is, therefore, worth reconsidering these indication criteria by introducing novel testing procedures. The diagnostic evidence collected will be evaluated. The investigation includes postlingually deafened adults seeking a CI. Prior to surgery, speech perception tests [Freiburg Speech Test and Oldenburg sentence (OLSA) test] were performed unaided and aided using the Oldenburg Master Hearing Aid (MHA) system. Linguistic skills were assessed with the visual Text Reception Threshold (TRT) test, and general state of health, socio-economic status (SES) and subjective hearing were evaluated through questionnaires. After surgery, the speech tests were repeated aided with a CI. To date, 97 complete data sets are available for evaluation. Statistical analyses showed significant correlations between postsurgical speech reception threshold (SRT) measured with the adaptive OLSA test and pre-surgical data such as the TRT test (r=-0.29), SES (r=-0.22) and (if available) aided SRT (r=0.53). The results suggest that new measures and setups such as the TRT test, SES and speech perception with the MHA provide valuable extra information regarding indication for CI

    Studies on using the SynFace talking head for the hearing impaired

    No full text
    SynFace is a lip-synchronized talking agent which is optimized as a visual reading support for the hearing impaired. In this paper we present the large scale hearing impaired user studies carried out for three languages in the Hearing at Home project. The user tests focus on measuring the gain in Speech Reception Threshold in Noise and the effort scaling when using SynFace by hearing impaired people, where groups of hearing impaired subjects with different impairment levels from mild to severe and cochlear implants are tested. Preliminary analysis of the results does not show significant gain in SRT or in effort scaling. But looking at large cross-subject variability in both tests, it is clear that many subjects benefit from SynFace especially with speech with stereo babble

    Comparing Binaural Pre-processing Strategies II

    No full text
    Several binaural audio signal enhancement algorithms were evaluated with respect to their potential to improve speech intelligibility in noise for users of bilateral cochlear implants (CIs). 50% speech reception thresholds (SRT 50 ) were assessed using an adaptive procedure in three distinct, realistic noise scenarios. All scenarios were highly nonstationary, complex, and included a significant amount of reverberation. Other aspects, such as the perfectly frontal target position, were idealized laboratory settings, allowing the algorithms to perform better than in corresponding real-world conditions. Eight bilaterally implanted CI users, wearing devices from three manufacturers, participated in the study. In all noise conditions, a substantial improvement in SRT 50 compared to the unprocessed signal was observed for most of the algorithms tested, with the largest improvements generally provided by binaural minimum variance distortionless response (MVDR) beamforming algorithms. The largest overall improvement in speech intelligibility was achieved by an adaptive binaural MVDR in a spatially separated, single competing talker noise scenario. A no-pre-processing condition and adaptive differential microphones without a binaural link served as the two baseline conditions. SRT 50 improvements provided by the binaural MVDR beamformers surpassed the performance of the adaptive differential microphones in most cases. Speech intelligibility improvements predicted by instrumental measures were shown to account for some but not all aspects of the perceptually obtained SRT 50 improvements measured in bilaterally implanted CI users

    Comparing Binaural Pre-processing Strategies I

    No full text
    In a collaborative research project, several monaural and binaural noise reduction algorithms have been comprehensively evaluated. In this article, eight selected noise reduction algorithms were assessed using instrumental measures, with a focus on the instrumental evaluation of speech intelligibility. Four distinct, reverberant scenarios were created to reflect everyday listening situations: a stationary speech-shaped noise, a multitalker babble noise, a single interfering talker, and a realistic cafeteria noise. Three instrumental measures were employed to assess predicted speech intelligibility and predicted sound quality: the intelligibility-weighted signal-to-noise ratio, the short-time objective intelligibility measure, and the perceptual evaluation of speech quality. The results show substantial improvements in predicted speech intelligibility as well as sound quality for the proposed algorithms. The evaluated coherence-based noise reduction algorithm was able to provide improvements in predicted audio signal quality. For the tested single-channel noise reduction algorithm, improvements in intelligibility-weighted signal-to-noise ratio were observed in all but the nonstationary cafeteria ambient noise scenario. Binaural minimum variance distortionless response beamforming algorithms performed particularly well in all noise scenarios
    corecore